Interior
Building characteristics:
  • One storey structure with second level office block, 7 and 11 meter clear heights
  • Floor loading capacity of 3,000 kg/sq m, with a point load of 5,000 kg
  • Concrete or steel columns and structural steel beams
  • Concrete slab with surface hardener by quartz application
  • Column bay spacing of approximately 240 m2
  • Aluminum window and door frames
  • Insulated panel or composite cladding
Dock levelers:
  • Electrical operation type maximum bearing load of 9,000 kg static, 6,000 kg dynamic
  • One dock per approx. 1,000 sq m
Fire Protection:
  • ESFR sprinkler system in 11 meter warehouse with onsite tank with engineered capacity
  • Interior fire hydrants/hoses in warehouse area per local codes requirements
  • Smoke detection and fire traps per code requirements
Heating / Ventilation:
  • Gas heating system to maintain 15 degrees C in the warehouse when -15 degrees C exterior
Electrical Section:
  • Main and secondary electrical panel boards
  • 220/380 volts power connections
  • Interior Lighting 150 lux
  • Emergency lighting/exit signs as required at all emergency exit locations (per code)
Offices
  • Fit-out on ground floor and mezzanine
  • Walls 50 mm covered with interior gypsum board
  • Interior separation walls in standard gypsum board
  • All interior walls painted
  • Windows in aluminum frames
  • Gas heating system to maintain 20 degrees C at office zone, 18 degrees C at sanitary and other interior spaces when - 15 degrees C exterior
  • 400 lux interior lighting
  • Quantity of 2 (16A + E) electrical outlets for each work station
  • 3 compartment trunking for tenants bespoke fit-out
Exterior
  • Ample truck parking and car parking on premises
  • Landscaping as required
  • Truck Court of approx. 35 meters
  • 2 meter high security fence around the entire park
  • Paving on concrete in truck zone and passenger car parking areas
  • Concrete curbs
  • Drainage pipes
  • Sanitary sewer lines
  • Water line
  • Electrical duct and service
  • Telephone network and ducts
  • Sprinkler line from tank to building
  • Exterior lighting Via low voltage console panel
  • Lighting columns at the truck access and waiting point, round-topped lighting posts
  • Lighting level of 15 lux on truck court

Minimum take up for logistics warehouses 2.000 sq m
Minimum take up for multi-let warehouses 300 sq m

Disclaimer:
This Outline Specification has been carefully drafted by HeliosPhoenix. However, no contractual right or obligation can be derived from this information prior to the executing of a legally binding lease agreement between HeliosPhoenix and the Customer. This information can be changed anytime by HeliosPhoenix and without prior notice.